Dryer tumbling but blowing cold air
A Whirlpool, Maytag, Samsung, LG or GE dryer that turns but won't heat usually comes down to one of these: half of a tripped breaker, a closed gas valve, a burned-out heating element, a blown thermal fuse, a failed thermostat, a cracked igniter or tired gas valve coils, or a vent packed with lint.
Electric dryers run on a 240-volt, 30-amp circuit fused on both sides of the line, Whirlpool explains, so there are two breakers. One side can keep the motor turning while the other side, the one feeding the heating element, has tripped. That's why a drum that spins with no heat at all gets its power checked on both legs before anyone opens the cabinet.
On a gas dryer, the shutoff valve on the pipe behind the machine is the first stop. Whirlpool's rule: handle parallel to the pipe is open, crosswise is closed. A closed valve lets the drum spin normally with no heat, and a valve gets bumped easily when a dryer is pulled out or moved into a new house. Tell us on the call if the dryer was moved lately.
With power and gas confirmed, the fault is inside. Reaching the heating element or the thermal fuse means taking the dryer apart, and the tech tests the fuse, the high-limit and cycling thermostats, and then the element or the ignition parts, depending on the fuel.
Gas and electric dryer heating repair
The drum, belt and motor work the same on both. The heat source is where they split.
Electric dryers
- A coiled heating element warms the air. When the coil breaks, the dryer runs cold, and replacing it runs $150 to $350 nationally.
- The element itself runs about $15 to $35 as a generic part, or up to $200 from the maker.
- A half-tripped breaker or a loose wire at the cord terminal block can look exactly like a dead element.
- A high-limit thermostat that keeps tripping usually means the exhaust is being held back somewhere.
Gas dryers
- A hot-surface igniter glows to light the burner. A cracked one stays dark, and the drum turns with no flame.
- If the igniter glows but the flame never catches, weak gas valve coils are a common cause.
- A faulty flame sensor can leave the igniter glowing while no gas flows.
- Work on the gas connection itself falls under Texas plumbing law, and how a repair visit works explains who handles it.
Loads taking two cycles, squealing and other dryer faults
Once heat is ruled in or out, most dryer problems show up as one of these.
Dryer heats, but a load takes two cycles
Dryer quit heating right after the vent got clogged
Dryer squealing, thumping or scraping at the drum
Dryer motor hums but the drum won't turn
Dryer shuts off mid-cycle, or the top feels unusually hot
Dryer dead: no lights, no hum
Overheating dryer and gas odor problems
Stop and do these before anything else.
- Scorched smell, or a cabinet too hot to keep a hand on: stop the dryer, unplug it and leave it off until the vent has been checked end to end.
- Motor straining or humming without turning the drum: switch it off so the motor doesn't overheat.
- Smell gas near a gas dryer: leave the house on foot without flipping switches or starting a car, and report the leak to your gas company from outside before anything else.
- Once everyone is safe, call us and tell us what you saw or smelled.
Clogged or crushed dryer vent
Lint that gets past the screen ends up in the duct, and a dryer pushing against a clogged duct runs hot and slow. Failure to clean is the leading cause of dryer fires in residential buildings: 34% of an estimated 2,900 a year in U.S. Fire Administration figures for 2008 to 2010.
Plenty of newer dryers flag it themselves. Samsung shows C8, C9 or Clg after its vent blockage test and points to the lint screen and exhaust vent for its tE and hE heat codes too. Whirlpool shows AF or Check Vent and keeps running while the warning is up. LG's d90 and d95 mean the dryer has measured a 90% or 95% blockage, and LG says not to use it until the exhaust has been cleaned. The appliance error code library lists the rest.
On the visit the tech checks the connector behind the dryer for kinks and crushing, the run to the outside for lint, and the flap at the wall or the cap on the roof. A laundry room in the middle of the house that vents through the roof is a much longer job than a short run straight out a back wall, and a crushed foil or white vinyl connector gets swapped for a metal one. Vent cleaning and a new duct both have a line on the price table below.
Whirlpool's interval for cleaning the vent run is every one to two years, sooner once loads start taking longer.
What dryer repairs cost
National averages, parts and labor included, with the typical dryer repair around $200. The price for your dryer comes in writing after the diagnosis, and the tech doesn't swap a part until you say yes.
| Repair | Typical range | Notes |
|---|---|---|
| Service call and diagnosis | $70 to $130 | |
| Thermal fuse | $75 to $150 | The fuse alone is $5 to $10 generic, up to $60 from the maker |
| Gas igniter | $100 to $250 | |
| Belt | $100 to $250 | |
| Drum rollers | $100 to $300 | |
| Timer | $120 to $300 | |
| Heating element | $150 to $350 | Electric models |
| Motor | $150 to $400 | |
| Idler pulley | $200 to $350 | |
| Drum | $200 to $500 | |
| Control board | $250 to $500 | |
| Vent cleaning | $80 to $185 | New duct: $100 to $300 |
A new dryer averages $800 to $1,200 nationally. For washer, fridge and kitchen repair prices, see the appliance repair cost guide.
Is an older dryer worth repairing?
Dryers are simple machines and they last. NAHB's life-expectancy figures put a dryer at about 13 years, a few more than the washer next to it. Most dryer parts also sit low on the price table, so a belt, fuse, roller kit or igniter on a 10-year-old dryer is usually money well spent.
The math turns when the big parts go. A $500 control board or drum on a 12-year-old dryer is close to half the $800 to $1,200 price of a new one, which is the 50% point Consumer Reports uses for repair or replace. Maytag's 10-year limited parts warranty covers the dryer's drive motor and drum (parts only after the first year), which can change the answer, so have the purchase date handy. The repair or replace guide walks through the same test for other appliances, and the Maytag dryer repair page has that brand's terms.
Dryer types and brands repaired
When you call, give us the brand, whether it runs on gas or electric, and roughly how long a normal load takes now. On a front-load Maytag dryer, open the door and look around the opening for the model label. Whirlpool Corporation owns the Maytag, Amana and KitchenAid brands, and the Whirlpool appliance repair page covers its codes and warranty. Dryer calls are taken in Houston and in parts of the cities next door, including Bellaire, Stafford, Missouri City and Sugar Land; the service areas page lists covered ZIPs. Don't see your ZIP? Call anyway and we'll check your address.
Dryer repair and vent questions
How do I know if my dryer vent is clogged?
Long drying times are the first sign the CPSC names. A cabinet that runs hot and a weak puff of air at the outside flap point the same way. Samsung, Whirlpool and LG dryers may also flag it with a vent code such as C8, AF or d90. The tech checks the duct and the flap on the visit.
Can I keep using my dryer if the vent is clogged?
Better not. A restricted vent drives exhaust temperatures up and trips safety parts, and the U.S. Fire Administration lists failure to clean as the leading factor in residential dryer fires. Leave it off and call. The tech clears the vent before replacing any fuse it blew.
Why does my gas dryer heat for a while and then go cold?
Weak gas valve coils are a common cause. They can open the valve while cool and fail once warm, so the burner lights, goes out and won't relight. A cycling thermostat or a vent restriction tripping the high-limit can look the same, so the tech tests the airflow and the coils together.
How much does a dryer thermal fuse cost to replace?
$75 to $150 installed, going by national averages, with the fuse itself $5 to $10 generic or up to $60 from the maker. The fuse is the easy half of the job. A blocked vent is what usually blows it, so the tech checks the vent before calling the repair done.